3 Phase 22kw 37kw 75kw Motor Soft Starter for Three Phase Induction Motor

AST1 series smart motor soft starter is new equipment based on the latest motor control theory, proprietary motor protection technology and advanced software technology. It's the ideal replacement of former starting equipment such as star/delta transformation, auto transformer voltage...

Send InquiryChat Now

Product Details

AST1 series smart motor soft starter is new equipment based on the latest motor control theory, proprietary motor protection technology and advanced software technology. It's the ideal replacement of former starting equipment such as star/delta transformation, auto transformer voltage reduction, and magnetic control voltage reduction, etc. Its performance is far beyond that of most ordinary soft starters in the marketplace which do not include the intelligent starting control technology.

 

1、Reduce the motor's starting current effectively, reduce the capacity of power distribution and avoid investment of grid expansion.

2、Reduce the starting stress of motor and load equipment; Prolong the motor and related equipment's service life.

3、Soft stop function can effectively solve surge problem during stop of inertial systems that traditional starting equipment can't achieve.

4、It has six unique starting modes to suit the complex motor and load condition to achieve perfect start effect.

5、Complete and reliable protection function protects the motor and related production equipment to be used safely.

6、The intelligent of motor soft starter and the application of network technology makes the motor control technology adapt to the higher requirements of fast developing power automation technology.


Specification of Inilion Soft Starter

 

Basic parameter

Three-phase voltage(U)

VAC

200 - 690

Frequency

Hz

50/60

Nominal current

A

10 -1000, total 24 kinds of rated values

Motor power

KW

5.5 - 630

 

Adjusting current

The nominal current In of motor can be adjusted within 1.2~5 times of starter rated current.

 

Starting mode

The starting current is limited to 5In, the factory default setting: when the torque integral is 16s, the limit of starting current of standard load is 3In,and when the torque integration is 15s, the limit of starting current of heavy load is 3.5In.

 

Stopping mode

Free stop

Soft stop for 4s

Soft stop

Be programmable and adjustable from 0.5~60s

Brake stop

Be programmable and adjustable from 0.5~60s (according to order agreement)

 

Display and keyboard

When the equipment runs normally, the display can show the operating current of motor (or current percentage), when the equipment occurs fault, the display can show the information of fault, and the keyboard can be used to set the parameter, contact function and locking stop.

 

Output relay(2pcs.)

Min switching capability

V/A

100mA~24V

Nominal working current

A

0.5,class AC-15(240VAV)and DC-13 (48VDC)

Mechanical life

 

Operate 0.5 billions times

 

Voltage:3AC 200V-690V

Power: : 5.5KW-630KW

380v Selection table for 75kw and below soft starter. More details please contact us.

75kw and below_副本.jpg 


Certificate:

CE(EN 60947-1:2007+A2:2014,EN 60947-4-2:2012;EN 61000-6-4:2007+A1:2011,EN 61000-6-2:2005+AC:2005), Report No and Date : AB-170517-L, AB-170517-E/ 2017-5-17

ISO9001:2008,CCC and reports, etc..

 

Inquiry